PA12 VESTAMID® L L2123 Altuglas International of Arkema Inc.
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -30°C,Complete Break | ISO 179/1eA | 13 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | NoBreak | |
| -30°C | ISO 179/1eU | NoBreak | ||
| Charpy Notched Impact Strength | 23°C,Partial Break | ISO 179/1eA | 120 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.2mm | UL 94 | HB | |
| 1.6mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 370 | MPa | |
| tensile strength | Yield | ISO 527-2 | 24.0 | MPa |
| Tensile strain | Yield | ISO 527-2 | 32 | % |
| Break | ISO 527-2 | >50 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 171 | °C | |
| Vicat softening temperature | -- | ISO 306/B | 120 | °C |
| -- | ISO 306/A | 165 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 45.0 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 80.0 | °C | |
| Linear coefficient of thermal expansion | MD:23to55°C | ISO 11359-2 | 1.8E-04 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.60 | % |
| Shrinkage rate | MD | ISO 294-4 | 0.65 | % |
| TD | ISO 294-4 | 1.4 | % | |
| density | 23°C | ISO 1183 | 1.03 | g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionA3 | IEC 60112 | PLC 0 | |
| -- | IEC 60112 | PLC 0 | ||
| Dissipation factor | 23°C,1MHz | IEC 60250 | 0.11 | |
| 23°C,100Hz | IEC 60250 | 0.20 | ||
| Relative permittivity | 23°C,1MHz | IEC 60250 | 3.60 | |
| 23°C,100Hz | IEC 60250 | 10.0 | ||
| Dielectric strength | IEC 60243-1 | 29 | kV/mm | |
| Volume resistivity | IEC 60093 | 1E+12 | ohms·cm | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ISO Shortcut | ISO 1874 | PA12-P.EHL.22-004 | ||
| Electrolytic corrosion | IEC 60426 | A1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.