Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.83 g/cm³ |
Water absorption rate | Equilibrium | ASTM D229 | 0.20 % |
hardness | Test Condition | Test Method | Test Result |
---|
Barcol Hardness | | | 64 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Radiation board grade | | ASTME162 | 1.30 |
Smoke density | | ASTME662 | 40 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Viscosity | | ASTM D229 | 9.65 MPa |
Temperature rating | | | 130 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D638 | 64.8 MPa |
Flexural modulus | | ASTM D790 | 11000 MPa |
bending strength | | ASTM D790 | 145 MPa |
compressive strength | | ASTM D695 | 241 MPa |
shear strength | | ASTM D732 | 96.5 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 430 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | ASTM D150 | 4.73 |
dielectric constant | | ASTM D150 | 4.69 |
Dissipation Factor | | ASTM D150 | 0.016 |
Dissipation Factor | | ASTM D150 | 0.011 |
arc resistance | | ASTM D495 | 185 sec |
Compared to the Leakage Tracking Index (CTI) | | | PLC 1 |
Inclined plate electric trace | | ASTM D2303 | 500 min |
dielectric strength | | ASTM D149 | 55000 V |
dielectric strength | | ASTM D149 | 18 kV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.