Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO 294-4 | 0.74 % |
Shrinkage rate | | ISO 294-4 | 0.43 % |
Water absorption rate | | ISO 62 | 0.40 % |
Water absorption rate | | ISO 62 | 0.20 % |
density | | ISO 1183 | 1.39 g/cm³ |
Melt volume flow rate | | ISO 1133 | 20.0 cm³/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | | ISO 527-2 | 2.7 % |
Tensile modulus | | ISO 527-2 | 6900 MPa |
tensile strength | | ISO 527-2 | 160 MPa |
tensile strength | | ISO 527-2 | 100 MPa |
tensile strength | | ISO 527-2 | 68.0 MPa |
tensile strength | | ISO 527-2 | 42.0 MPa |
Tensile strain | | ISO 527-2 | 2.5 % |
Tensile strain | | ISO 527-2 | 4.2 % |
Tensile strain | | ISO 527-2 | 7.4 % |
Tensile strain | | ISO 527-2 | 6.7 % |
Flexural modulus | | ISO 178 | 6400 MPa |
tensile strength | | ISO 527-2 | 32.2 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179 | 7.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 43 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 55 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180 | 7.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | 1E+14 ohms |
Volume resistivity | | IEC 60093 | >1.0E+15 ohms·cm |
dielectric constant | | IEC 60250 | 3.70 |
dielectric constant | | IEC 60250 | 3.60 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 1 |
Dissipation Factor | | IEC 60250 | 3E-03 |
Dissipation Factor | | IEC 60250 | 0.019 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/B | 205 °C |
Heat distortion temperature | | ISO 75-2/A | 160 °C |
melting temperature | | ISO 3146 | 223 °C |
Linear coefficient of thermal expansion | | | 4E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.