Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO1183/A | 1.47 g/cm³ |
Melt volume flow rate | | ISO1133 | 7.00 cm³/10min |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94,IEC60695-11-10,-20 | V-0 |
UL flame retardant rating | | UL94,IEC60695-11-10,-20 | V-0 |
UL flame retardant rating | | UL94,IEC60695-11-10,-20 | V-0 |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 850 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 850 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 850 °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 13 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179 | 65 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 7.9 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 68 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1A/1 | 8500 MPa |
Tensile stress | Break | ISO527-2/5 | 130 MPa |
Tensile strain | Break | ISO527-2/5 | 4.5 % |
Flexural modulus | | ISO178 | 8800 MPa |
Bending stress | | ISO178 | 190 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
CTI | | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
vicat | | ISO306/B50 | 208 °C |
| | ISO75-2/Af | 206 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.