ABS SR-0320K Samsung Cheil South Korea
86
Form:Granules | Grade:Heat resistant grade
Properties:
High mobilityHigh impact resistanceheat-resisting High impact resistanceHigh liquidity
Typical Applications:
Automotive ApplicationsElectrical enclosureAutomotive accessories such as rearview mirrorsControl panel
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Electrical enclosure | Automotive accessories such as rearview mirrors | Control panel |
| Properties: | High mobility | High impact resistance | heat-resisting | High impact resistance | High liquidity |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| bending strength | 2.8mm/min | ASTM D-790 | 650 | Kgf/cm2 |
| Impact strength of cantilever beam gap | 1/8" | ASTM D-256 | 24 | Kgf.cm/cm |
| Rockwell hardness | R-Scale | ASTM D-785 | 106 | R-Scale |
| tensile strength | 5mm/min | ASTM D-638 | 450 | Kgf/cm2 |
| Bending modulus | 2.8mm/min | ASTM D-790 | 22000 | Kgf/cm2 |
| Impact strength of cantilever beam gap | 1/4" | ASTM D-256 | 19 | Kgf.cm/cm |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ASTM D-955 | 0.4-0.6 | % | |
| UL flame retardant rating | UL 94 | 1.5HB | Recognized | |
| Hot deformation temperature | 1/4" 1.8MPa | ASTM D-648 | 96 | °C |
| Vicat softening temperature | B/50 | ASTM D-1525 | 107 | °C |
| Hot deformation temperature | 1/4" 1.8MPa | ASTM D-648 | 205 | ℉ |
| Vicat softening temperature | B/50 | ASTM D-1525 | 225 | ℉ |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 200℃/10kg | ASTM D-1238 | 8.0 | g/10min |
| density | 23℃ | ASTM D-792 | 1.05 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.