PC/ABS CX7240-701 SABIC INNOVATIVE NANSHA
126
Form:Granules | Grade:Injection grade
Properties:
Flame retardantHigh impact resistanceHigh mobility
Typical Applications:
Electrical fieldElectronic fieldArchitectural application fieldOutdoor applicationsEngine hood partsMedical suppliesNursing suppliesPlastic bagCastersAerospace ApplicationsLiquid handling
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Architectural application field | Outdoor applications | Engine hood parts | Medical supplies | Nursing supplies | Plastic bag | Casters | Aerospace Applications | Liquid handling |
| Properties: | Flame retardant | High impact resistance | High mobility |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -30°C7 | ISO 179/1eA | 10 | kJ/m² |
| 23°C8 | ISO 179/1eA | 22 | kJ/m² | |
| 23°C7 | ISO 179/1eA | 20 | kJ/m² | |
| Impact strength of cantilever beam gap | -30°C | ASTM D256 | 180 | J/m |
| 23°C | ASTM D256 | 700 | J/m | |
| -30°C9 | ISO 180/1A | 10 | kJ/m² | |
| -30°C10 | ISO 180/1A | 10 | kJ/m² | |
| 23°C9 | ISO 180/1A | 25 | kJ/m² | |
| 23°C10 | ISO 180/1A | 20 | kJ/m² | |
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 65.0 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Hot filament ignition temperature | 3.0mm | IEC 60695-2-13 | 800 | °C |
| Extreme Oxygen Index | ISO 4589-2 | 35 | % | |
| UL flame retardant rating | 0.60mm | UL 94 | V-1 | |
| 0.75mm | UL 94 | V-0 | ||
| 1.5mm | UL 94 | 5VB | ||
| 3.0mm | UL 94 | 5VA | ||
| Burning wire flammability index | 0.75mm13 | IEC 60695-2-12 | 960 | °C |
| 0.75mm | IEC 60695-2-12 | 960 | °C | |
| Hot filament ignition temperature | 0.75mm13 | IEC 60695-2-13 | 775 | °C |
| 1.0mm | IEC 60695-2-13 | 825 | °C | |
| 1.5mm13 | IEC 60695-2-13 | 775 | °C | |
| 3.0mm13 | IEC 60695-2-13 | 775 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 2600 | Mpa | |
| ISO 527-2/1 | 2600 | Mpa | ||
| tensile strength | Yield | ASTM D638 | 65.0 | Mpa |
| Yield | ISO 527-2/50 | 65.0 | Mpa | |
| Break | ASTM D638 | 58.0 | Mpa | |
| Break | ISO 527-2/50 | 50.0 | Mpa | |
| elongation | Yield | ASTM D638 | 4.1 | % |
| Tensile strain | Yield | ISO 527-2/50 | 4.0 | % |
| elongation | Break | ASTM D638 | 100 | % |
| Tensile strain | Break | ISO 527-2/50 | 90 | % |
| Bending modulus | 50.0mmSpan | ASTM D790 | 2500 | Mpa |
| ISO 178 | 2500 | Mpa | ||
| bending strength | ISO 178 | 96.0 | Mpa | |
| Yield,50.0mmSpan | ASTM D790 | 104 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed,3.20mm | ASTM D648 | 100 | °C |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 89.0 | °C | |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 99.0 | °C | |
| 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 93.0 | °C | |
| Vicat softening temperature | ASTM D152512 | 110 | °C | |
| -- | ISO 306/B50 | 110 | °C | |
| -- | ISO 306/B120 | 113 | °C | |
| Ball Pressure Test | 75°C | IEC 60695-10-2 | Pass | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 7.5E-05 | cm/cm/°C |
| MD:-40to40°C | ISO 11359-2 | 7.5E-05 | cm/cm/°C | |
| TD:-40to40°C | ASTME831 | 7.5E-05 | cm/cm/°C | |
| TD:-40to40°C | ISO 11359-2 | 7.5E-05 | cm/cm/°C | |
| thermal conductivity | ISO 8302 | 0.20 | W/m/K | |
| RTI Elec | UL 746 | 90.0 | °C | |
| RTI Imp | UL 746 | 90.0 | °C | |
| RTI Str | UL 746 | 90.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation,23°C | ISO 62 | 0.20 | % |
| Equilibrium,23°C,50%RH | ISO 62 | 0.10 | % | |
| density | ASTM D792 | 1.19 | g/cm³ | |
| ISO 1183 | 1.20 | g/cm³ | ||
| melt mass-flow rate | 260°C/2.16kg | ASTM D1238 | 18 | g/10min |
| Melt Volume Flow Rate (MVR) | 260°C/2.16kg | ISO 1133 | 15.0 | cm3/10min |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.40-0.60 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Dielectric strength | 0.800mm,in Oil | IEC 60243-1 | 35 | KV/mm |
| 1.60mm,in Oil | IEC 60243-1 | 25 | KV/mm | |
| 3.20mm,in Oil | IEC 60243-1 | 17 | KV/mm | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 3 | |
| High arc combustion index | HAI | UL 746 | PLC 0 | |
| Hot wire ignition | HWI | UL 746 | PLC 3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.