ABS POLYLAC® D-150
789
- Properties:High rigidityHigh gloss
- Usages:Household goodsToyHome appliance componentsElectrical fieldElectronic fieldElectrical enclosure
- Certificates:UL
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ASTM D-955 | 0.4-0.6 % |
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | ASTM D-1238 | 1.6 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D-638 | 460 Kgf/cm2 | |
Impact strength of cantilever beam gap | ASTM D-256 | 18 Kgf.cm/cm | |
Flexural modulus | ASTM D-790 | 2450 Kgf/cm2 | |
Rockwell hardness | ASTM D-785 | 105 M Scale | |
bending strength | ASTM D-790 | 735 Kgf/cm2 | |
tensile strength | ASTM D638/ISO 527 | 470 kg/cm²(MPa)[Lb/in²] | |
Rockwell hardness | ASTM D785 | R-110 | |
Flexural modulus | ASTM D790/ISO 178 | 780 kg/cm²(MPa)[Lb/in²] | |
Charpy Notched Impact Strength | ASTM D256/ISO 179 | 22 kg·cm/cm(J/M)ft·lb/in | |
Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 20 kg·cm/cm(J/M)ft·lb/in |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792/ISO 1183 | 1.05 | |
Shrinkage rate | ASTM D955 | 0.4-0.6 % | |
melt mass-flow rate | ASTM D1238/ISO 1133 | 1.5 g/10min |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D-648 | 87 °C | |
ASTM D-648 | 189 ℉ | ||
combustibility | UL -94 | 1/16"HB | |
Heat distortion temperature | ASTM D648/ISO 75 | 87 ℃(℉) |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.