PA46 Stanyl®  SF5030 BK

57
  • Properties:
    Thermal stability
    Flame retardant
  • Usages:
    Fitness equipment
    Electronic and electrical components

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.68 g/cm³
Shrinkage rateISO 294-41.1 %
Shrinkage rateISO 294-40.40 %
Water absorption rateISO 621.6 %
flammabilityTest ConditionTest MethodTest Result
Flammability levelUL 94V-0
Flammability levelUL 94V-0
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-212000 Mpa
tensile strength ISO 527-2170 Mpa
Tensile strainISO 527-21.9 %
Flexural modulusISO 17811000 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA12 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA13 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU40 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityIEC 60093> 1.0E+15 ohms·cm
dielectric strengthIEC 60243-130 KV/mm
relative permittivityIEC 602504.30
relative permittivityIEC 602504.00
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B290 °C
Heat distortion temperatureISO 75-2/A290 °C
melting temperatureISO 11357-3295 °C
Linear coefficient of thermal expansionISO 11359-22.0E-5 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-24.5E-5 cm/cm/°C
RTI ElecUL 74665.0 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.