Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30°CISO 179/1eA12kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA13kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU40kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Flammability levelUL 94V-0
Flammability levelUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-212000Mpa
tensile strengthBreakISO 527-2170Mpa
Tensile strainBreakISO 527-21.9%
Bending modulusISO 17811000Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45 MPa, UnannealedISO 75-2/B290°C
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A290°C
Melting temperatureISO 11357-3295°C
Linear coefficient of thermal expansionFlowISO 11359-22.0E-5cm/cm/°C
Linear coefficient of thermal expansionAcross FlowISO 11359-24.5E-5cm/cm/°C
RTI Elec0.35 mmUL 74665.0°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.68g/cm³
Shrinkage rate横向FlowISO 294-41.1%
Shrinkage rateFlowISO 294-40.40%
Water absorption rateEquilibrium, 23°C, 50% RHISO 621.6%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityIEC 60093> 1.0E+15ohms·cm
Dielectric strengthIEC 60243-130KV/mm
Relative permittivity100 HzIEC 602504.30
Relative permittivity1 MHzIEC 602504.00
Compared to the anti leakage trace indexIEC 60112PLC 3
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.