ABS GP-2100 LG CHEM KOREA
60
Form:Granules | Grade:Enhanced level
Typical Applications:
Home appliance components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Home appliance components |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D-256 | 15.0 | kg.cm/cm | |
| ASTM D-256 | - | kg.cm/cm | ||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | ASTM D-638 | 660 | kg/cm2 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | ASTM D-638 | 3 | % | |
| bending strength | ASTM D-790 | 1000 | kg/cm2 | |
| Rockwell hardness | ASTM D-785 | 114 | R | |
| Shrinkage rate | 2-3 | cm/cm×0.0001 | ||
| Bending modulus | ASTM D-790 | 40000 | kg/cm2 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | ASTM D-696 | 4.5×0.000005 | mm/mm/ºC | |
| UL flame retardant rating | HB(1/16") | |||
| Thermal refraction temperature | ASTM D-648 | 95 | ºC | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D-792 | 1.10 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.