LCP E820I CELANESE USA
63
Form:Granules | Grade:Enhanced level
Properties:
Flame retardantHigh mobilityheat-resisting
Typical Applications:
Fitness equipmentHome appliance componentsAutomotive Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Fitness equipment | Home appliance components | Automotive Applications |
| Properties: | Flame retardant | High mobility | heat-resisting |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 28 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 30 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break | ISO 527-2/1A/5 | 89.0 | Mpa |
| Tensile modulus | ISO 527-2/1A/1 | 8000 | Mpa | |
| Bending strain | ISO 178 | 3.2 | % | |
| bending strength | 23°C | ISO 178 | 120 | Mpa |
| Bending modulus | 23°C | ISO 178 | 8800 | Mpa |
| Tensile strain | Break | ISO 527-2/1A/5 | 3.6 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 4.9E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 2.3E-05 | cm/cm/°C | |
| Hot deformation temperature | 8.0MPa,Unannealed | ISO 75-2/C | 119 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 215 | °C | |
| 0.45MPa,Unannealed | ISO 75-2/B | 255 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.40 | % |
| TD | ISO 294-4 | 1.2 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | ||
| Dissipation factor | 1MHz | IEC 60250 | 0.016 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.