PA6 SCHULAMID® 6 GF 30 FR2 A LM WEISS 96.0342 LM A SCHULMAN USA

Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | glass fiber reinforced material | 30% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU30kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU25kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA5.0kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA4.0kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.8mmIEC 60695-11-10,-20V-0
UL flame retardant rating3.2mmUL 94V-0
UL flame retardant rating1.6mmUL 94V-0
UL flame retardant rating0.8mmUL 94V-0
Hot filament ignition temperature0.75mmIEC 60695-2-13750°C
Burning wire flammability index3.0mmIEC 60695-2-12960°C
Burning wire flammability index1.5mmIEC 60695-2-12960°C
Burning wire flammability index0.75mmIEC 60695-2-12960°C
UL flame retardant rating3.2mmIEC 60695-11-10,-20V-0
UL flame retardant rating1.6mmIEC 60695-11-10,-20V-0
Hot filament ignition temperature1.5mmIEC 60695-2-13750°C
Hot filament ignition temperature3.0mmIEC 60695-2-13775°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/1A/112700MPa
Bending modulusISO 17811900MPa
Tensile strainBreakISO 527-2/1A/51.5%
tensile strengthBreakISO 527-2/1A/5130MPa
bending strength2.0%StrainISO 178200MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Vicat softening temperature--ISO 306/B50205°C
Vicat softening temperature--ISO 306/A50225°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af200°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/Bf215°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 1183/A1.61g/cm³
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexIEC 60112PLC 2
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.