PA6 K224-HG6U DSM Additive Manufacturing
Properties:
Filler glass fiber reinforced material 33% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 33% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 220 | °C |
| 1.80MPaUnannealed | ISO 75-2/Af | 210 | °C | |
| Melting temperature | ISO 11357-3 | 220 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 2E-05 | cm/cm/°C |
| TD | ISO 11359-2 | 7E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.38 | g/cm³ | |
| Water absorption rate | 23°C,24hr | ISO 62 | 6.30 | % |
| 23°C,50RH | ISO 62 | 1.90 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 23°C | IEC 60250 | 5E-03 | 100Hz |
| 23°C | IEC 60250 | 0.015 | 1MHz | |
| Volume resistivity | IEC 60093 | 1E+14 | Ω.cm | |
| Dielectric strength | IEC 60243-1 | 30 | KV/mm | |
| Dielectric constant | 23°C | IEC 60250 | 3.50 | 100Hz |
| 23°C | IEC 60250 | 3.30 | 1MHz | |
| flame retardancy | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 0.71mm | |
| UL -94 | HB | 1.50mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.