ABS TE-10S DENKA JAPAN
71
Form:Granules | Grade:Injection grade
Properties:
High temperature resistantransparentHigh mobility
Typical Applications:
Electronic fieldAutomotive sectorElectrical field
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electronic field | Automotive sector | Electrical field |
| Properties: | High temperature resistan | transparent | High mobility |
Certificates

Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Total Light Transmittance | 2mmt | ISO 13468-1(JIS K7361) | 91 | % |
| turbidity | 2mmt | ISO 14782(JIS 7136) | 1.5 | % |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 200℃,49N | ISO 1133(JIS K7210) | 1.7 | g/10min |
| 220℃,98N | ISO 1133(JIS K7210) | 25 | g/10min | |
| density | 23℃ | ISO 1183(JIS K7112) | 1092 | kg/m3 |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ASTM D785 | 46 | ||
| Bending modulus | ASTM D790/ISO 178 | 2000(MPa) | kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 63(MPa) | kg/cm²(MPa)[Lb/in²] | |
| Tensile stress | 50mm/min | ISO 527-1 | 42 | Mpa |
| Bending modulus | 2m/min | ISO 178(JIS K7171) | 2000 | Mpa |
| bending strength | 2mm/min | ISO 178(JIS K7171) | 63 | Mpa |
| Charpy Notched Impact Strength | 23℃ | ISO 179(JIS K7111) | 15 | kJ/m² |
| Rockwell hardness | 23℃ | ISO 2039-2(JIS K7202) | 46 | M |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Combustibility (rate) | UL 94 | HB | ||
| Vicat softening temperature | ASTM D1525/ISO R306 | 87 | ℃(℉) | |
| Hot deformation temperature | 1.80MPa | ISO 75-1 | 70 | °C |
| Vicat softening temperature | 50N | ISO 306(JIS K7206) | 87 | °C |
| Combustibility | UL 94 | HB | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792/ISO 1183 | 1.09 | ||
| Shrinkage rate | ASTM D955 | 0.5 | % | |
| DENKA Method | 0.5 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.