Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTMD570 | 0.050 % |
density | | ASTMD792 | 1.82 g/cm³ |
Apparent density | | ASTMD1895 | 0.89 g/cm³ |
Shrinkage rate | | ASTMD955 | 0.35 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 58 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ASTMD256 | 16.1 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 16 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTMD638 | 13300 MPa |
tensile strength | | ASTMD638 | 39.0 MPa |
elongation | Break | ASTMD638 | 0.50 % |
Flexural modulus | | ASTMD790 | 11100 MPa |
bending strength | | ASTMD790 | 64.6 MPa |
compressive strength | | ASTMD695 | 128 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 180 °C |
Continuous use temperature | | ASTMD794 | 202 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.