PA46 Stanyl®  TS200F6

479
  • Properties:
    heat-resisting
    Flame retardant
  • Usages:
    Electronic and electrical components
    Electrical applications
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.41 g/cm³
Shrinkage rateISO 294-41.3 %
Shrinkage rateISO 294-40.50 %
Water absorption rateISO 622.6 %
flammabilityTest ConditionTest MethodTest Result
Flammability levelIEC 60695-11-10, -20HB
Flammability levelIEC 60695-11-10, -20HB
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-210000 Mpa
Tensile modulusISO 527-25500 Mpa
Tensile modulusISO 527-25000 Mpa
Tensile modulusISO 527-24400 Mpa
Tensile modulusISO 527-24000 Mpa
Tensile stressISO 527-2210 Mpa
Tensile stressISO 527-2110 Mpa
Tensile stressISO 527-2100 Mpa
Tensile stressISO 527-295.0 Mpa
Tensile stressISO 527-290.0 Mpa
Tensile strainISO 527-24.0 %
Tensile strainISO 527-27.5 %
Tensile strainISO 527-27.5 %
Tensile strainISO 527-27.5 %
Tensile strainISO 527-27.5 %
Flexural modulusISO 1789000 Mpa
Flexural modulusISO 1784700 Mpa
Flexural modulusISO 1783900 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA11 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA12 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU65 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU80 kJ/m²
Impact strength of cantilever beam gapISO 180/1A11 kJ/m²
Impact strength of cantilever beam gapISO 180/1A12 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityIEC 600931.0E+15 ohms·cm
dielectric strengthIEC 60243-135 KV/mm
IEC 602504.40
IEC 602504.00
CTIIEC 60112500 V
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B290 °C
Heat distortion temperatureISO 75-2/A290 °C
Melting temperature 3ISO 11357-3295 °C
ISO 11359-22.5E-5 cm/cm/°C
ISO 11359-26.0E-5 cm/cm/°C
RTI ElecUL 74665.0 °C
Thermal Index - 5000 hrIEC 60216152 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.