PC PANLITE® GV-3410R TEIJIN SHANGHAI
17
- Properties:High rigidityAnti creepFiller: Glass fiber reinf10% filler by weight
- Usages:Industrial applicationsElectrical fieldElectronic fieldIndustrial applicationsElectrical components
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | ISO 179 | 40 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 0.40mm | UL 94 | V-2 |
| 0.75mm | UL 94 | V-0 | |
| 2.5mm | UL 94 | 5VA |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | ISO 178 | 3800 Mpa | |
| bending strength | ISO 178 | 125 Mpa | |
| Tensile modulus | ISO 527-2/1 | 3900 Mpa | |
| tensile strength | Break | ISO 527-2/5 | 75.0 Mpa |
| Tensile strain | Break | ISO 527-2/5 | 3.5 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| RTI Imp | 1.5mm | UL 746 | 120 °C |
| RTI Str | 1.5mm | UL 746 | 130 °C |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 147 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 144 °C | |
| Vicat softening temperature | ISO 306/B50 | 149 °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 4E-05 cm/cm/°C |
| TD | ISO 11359-2 | 6E-05 cm/cm/°C | |
| RTI Elec | 1.5mm | UL 746 | 130 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | TD:4.00mm | Internal Method | 0.40-0.60 % |
| MD:4.00mm | Internal Method | 0.30-0.50 % | |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.16 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
| Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
| Dielectric strength | IEC 60243-1 | 35 KV/mm | |
| Relative permittivity | 100Hz | IEC 60250 | 3.20 |
| 1MHz | IEC 60250 | 3.20 | |
| Dissipation factor | 100Hz | IEC 60250 | 1E-03 |
| 1MHz | IEC 60250 | 9E-03 | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.