ABS AG15A0 FCFC TAIWAN
279
Form:Granules | Grade:Injection grade
Properties:
High rigidityCharacteristic: High rigiGeneral molding
Typical Applications:
FootwearToyShellElectrical appliancesPlastic boxheelToyClock housingAudio peripheralssuitcase.
Product Description
Certificates(3)
Datasheet
Alternative(1)
Product Description
| Typical Applications: | Footwear | Toy | Shell | Electrical appliances | Plastic box | heel | Toy | Clock housing | Audio peripherals | suitcase. |
| Properties: | High rigidity | Characteristic: High rigi | General molding |
Certificates



Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| melt mass-flow rate | 220℃×10kgf(98N) | ASTM D-1238(ISO 1133) | 19 | g/10min |
| 200℃×5kgf(49N) | ASTM D-1238(ISO 1133) | 1.7 | g/10min | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | 23℃ | ASTM D-638(ISO 527) | 530(52) | kg/cm2(MPa) |
| Bending modulus | 23℃ | ASTM D-790(ISO 178) | 27000(2650) | kg/cm2(MPa) |
| Rockwell hardness | 23℃ | ASTM D-785(ISO 2039/2) | R-110 | |
| Impact strength of cantilever beam gap | 23℃1/4 | ASTM D-256 | 20 | kg.cm/cm |
| bending strength | 23℃ | ASTM D-790(ISO 178) | 850(84) | kg/cm2(MPa) |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | Unanneaied 18.6kg/cm2(1/2"厚) | ASTM D-648(ISO 75/A) | 89 | °C |
| Vicat softening temperature | 1Kg load | ASTM D-1525(ISO R180) | 104 | °C |
| Hot deformation temperature | Annealed(8℃×8hr) | ASTM D-1238(ISO 1133) | 101 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D-792(ISO 1183) | 1.05 | 23℃/23℃ | |
| Combustibility | FILE NO. E162823 | UL -94 | 1/16"HB All Color |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.