PS PS 485 DIOKI d.d.
0
- Usages:Thin walled components engineering accessories
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180/4A | 8.0 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | Break | ISO 527-2 | 18.0 MPa |
| Yield | ISO 527-2 | 16.0 MPa | |
| Tensile modulus | ISO 527-2 | 2000 MPa | |
| Tensile strain | Break | ISO 527-2 | >35 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Vicat softening temperature | ISO 306/B50 | 82.0 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | 0.40to0.60 % | ||
| melt mass-flow rate | 230°C/1.2kg | ISO 1133 | 12 g/10min |
| Apparent density | ISO 60 | 0.60 g/cm³ | |
| density | ISO 1183 | 1.05 g/cm³ |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Sale | ISO 2039-2 | 55 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.