Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Huangdu Index | 380-780nm | ISO 17223 | <2 | |
| turbidity | 3.2mm | ASTM D1003 | <0.5 | % |
| Transmittance rate | 3.2mm | ASTM D1003 | 90 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | 23℃ | ISO 179 | 72 | kJ/m² |
| Impact strength of cantilever beam gap | 23℃ | ISO 180 | 66 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 2mm/min | ISO 178 | 2300 | Mpa |
| bending strength | 2mm/min | ISO 178 | 90 | Mpa |
| Tensile modulus | 1mm/min | ISO 527 | 2400 | Mpa |
| Tensile strain | 50mm/min | ISO 527 | >120 | % |
| tensile strength | Break50mm/min | ISO 527 | 70 | Mpa |
| Yield50mm/min | ISO 527 | 60 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| flammability | 1.5mm | UL 94 | HB | |
| Vicat softening temperature | B120, 4.0mm | ISO 306 | 148 | °C |
| Hot deformation temperature | 1.80MPa,4.0mm | ISO 75 | 127 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294 | 0.5-0.7 | % |
| Water absorption rate | 23℃,24h | ISO 62 | 0.2 | % |
| density | ISO 1183 | 1.2 | g/cm³ | |
| melt mass-flow rate | 300℃,1.2kg | ISO 1133 | 9 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | IEC 60250 | 150 | 1 MHz | |
| Dielectric strength | 1mm | IEC 60243 | 30 | KV/mm |
| Dielectric constant | IEC 60250 | 2.7 | 1 MHz | |
| Volume resistivity | 5min | IEC 60093 | 300000000000000000 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.