Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.04 g/cm³ |
density | | ISO1183 | 1.04 g/cm³ |
melt mass-flow rate | | ISO1133 | 15 g/10min |
Shrinkage rate | | ASTMD955 | 0.40to0.60 % |
Water absorption rate | | ASTMD570 | 0.30 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 105 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 310 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 290 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 200 J/m |
Charpy Notched Impact Strength | | ISO179/1eA | 26 kJ/m² |
Impact strength of cantilever beam gap | | ASTMD256 | 160 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 140 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 230 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Bending stress | | ISO178 | 63.0 Mpa |
Tensile modulus | | ISO527-2/1 | 2100 Mpa |
tensile strength | | ASTMD638 | 41.0 Mpa |
Tensile stress | | ISO527-2/50 | 44.0 Mpa |
elongation | | ASTMD638 | 40 % |
Tensile strain | | ISO527-2/50 | >10 % |
Flexural modulus | | ASTMD790 | 1960 Mpa |
| | ASTMD790 | 63.0 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface resistivity 5 | | ASTMD257 | >1.0E+16 ohms |
Volume resistivity | | ASTMD257 | >1.0E+16 ohms·cm |
Dielectric strength 6 | | ASTMD149 | 24 KV/mm |
dielectric constant | | ASTMD150 | 3.10 |
Dissipation Factor | | ASTMD150 | 6.5E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 85.0 °C |
| | ASTMD648 | 91.0 °C |
| | ISO75-2/A | 80.0 °C |
| | ASTMD696 | 7.6E-05 cm/cm/°C |
thermal conductivity | | ASTMC177 | 0.15 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.