PC 3413R-131 COVESTRO GERMANY
39
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedenhanceFlame retardant
Typical Applications:
Automotive sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector |
| Properties: | Glass fiber reinforced | enhance | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Dart impact | 23°C | ASTM D3029 | 5.00 | J |
| Impact strength of cantilever beam gap | ASTM D1822 | 67.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.0mm | UL 94 | V-0 | |
| 1.5mm | UL 94 | V-1 | ||
| 0.75mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | Yield,50.0mmSpan | ASTM D790 | 153 | Mpa |
| Bending modulus | 50.0mmSpan | ASTM D790 | 6610 | Mpa |
| elongation | Break | ASTM D638 | 2.0 | % |
| tensile strength | Break | ASTM D638 | 100 | Mpa |
| Taber abraser | 1000Cycles,1000g,CS-17Wheel | ASTM D1044 | 24.0 | mg |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | UL 746 | 120 | °C | |
| RTI Imp | UL 746 | 120 | °C | |
| RTI Str | UL 746 | 130 | °C | |
| thermal conductivity | ASTMC177 | 0.22 | W/m/K | |
| specific heat | ASTMC351 | 1130 | J/kg/°C | |
| Hot deformation temperature | 0.45MPa,Unannealed,6.40mm | ASTM D648 | 151 | °C |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 146 | °C | |
| Vicat softening temperature | ASTM D15255 | 165 | °C | |
| Linear coefficient of thermal expansion | MD:-40to95°C | ASTME831 | 2.2E-05 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C | ASTM D570 | 0.26 | % |
| 24hr | ASTM D570 | 0.14 | % | |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.10-0.30 | % |
| melt mass-flow rate | 300°C/5.0kg | ASTM D1238 | 19 | g/10min |
| 300°C/1.2kg | ASTM D1238 | 5.0 | g/10min | |
| Specific volume | ASTM D792 | 0.697 | cm³/g | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | >1.0E+17 | ohms·cm | |
| Dielectric strength | 3.20mm,inAir | ASTM D149 | 19 | KV/mm |
| Dielectric constant | 50Hz | ASTM D150 | 3.35 | |
| 60Hz | ASTM D150 | 3.35 | ||
| Hot wire ignition | HWI | UL 746 | PLC 0 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 | |
| High arc combustion index | HAI | UL 746 | PLC 4 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 5 | |
| Arc resistance | ASTM D495 | PLC7 | ||
| Dissipation factor | 1MHz | ASTM D150 | 7E-03 | |
| 60Hz | ASTM D150 | 1.1E-03 | ||
| 50Hz | ASTM D150 | 1.1E-03 | ||
| Dielectric constant | 1MHz | ASTM D150 | 3.31 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Sale | ASTM D785 | 92 | |
| R-Sale | ASTM D785 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.