Share
Add to Comparison

PCTG TX1001(箱装) EASTMAN USA

83

Form:Granules

Properties:
heat-resistingHydrolysis resistanceHigh impact resistanceProcessabilitytransparentChemical resistance
Typical Applications:
Electrical fieldElectronic fieldHousehold appliancesHousehold appliancesHousehold goodsFood service sector
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Electrical field | Electronic field | Household appliances | Household appliances | Household goods | Food service sector
Properties:heat-resisting | Hydrolysis resistance | High impact resistance | Processability | transparent | Chemical resistance

Certificates

No Data...

Technical Data Sheet

optical performanceTest ConditionTest MethodTest ResultTest Unit
transmissivityTotalASTM D100390.0%
turbidityASTM D1003<1.0%
impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap23°CASTM D4812NoBreak
Impact strength of cantilever beam gap23°CASTM D256980J/m
Impact strength of cantilever beam gap-40°CISO 18020kJ/m²
Impact strength of cantilever beam gap23°CISO 18093kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23°CASTM D6381550Mpa
Tensile modulus23°CISO 527-21550Mpa
tensile strengthYield,23°CASTM D63843.0Mpa
tensile strengthYield,23°CISO 527-243.0Mpa
tensile strengthBreak,23°CASTM D63853.0Mpa
tensile strengthBreak,23°CISO 527-258.0Mpa
elongationYield,23°CASTM D6386.0%
Tensile strainYield,23°CISO 527-27.0%
elongationBreak,23°CASTM D638210%
Tensile strainBreak,23°CISO 527-2190%
Bending modulus23°CASTM D7901550Mpa
Bending modulus23°CISO 1781500Mpa
bending strength23°CISO 17859.0Mpa
bending strengthYield,23°CASTM D79062.0Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedASTM D64899.0°C
Hot deformation temperature1.8MPa,UnannealedASTM D64885.0°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D7921.18g/cm³
Shrinkage rateMDASTM D9550.50-0.70%
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessR-Sale,23°CASTM D785112
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.