PC LUVOCOM® 50/CF/30 LEHVOSS Group
0
- Properties:Fillercarbon fiber reinforced material30%filler by weight
- Usages:Engineering accessoriesbusiness equipmentgearsmedicalnursingand sports equipment
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.35 g/cm³ | |
Shrinkage rate | ISO 294-4 | 0.1 % | |
ISO 294-4 | 0.3 % | ||
Water absorption rate | ISO 62 | <=0.2 % | |
melt mass-flow rate | ISO 1133 | 12 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
elongation at break | ISO 527-2 | 1.8 % | |
bending strength | ISO 178 | 225 MPa | |
Flexural modulus | ISO 178 | 15500 MPa | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 25 kJ/m² | |
tensile strength | ISO 527-2 | 150 MPa |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL -94 | V-0 1.50mm |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | <=1000 Ω.cm | ||
<=100 Ω.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/Af | 150 °C | |
vicat | ISO 306/A50 | 160 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 1.4E-05 cm/cm/°C | |
130 °C | |||
150 °C | |||
DIN 52612 | 0.700 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.