PA6 YH-3000 SINOPEC BALING
16
Form:Granules | Grade:Injection grade
Properties:
wear resistanthigh strengthhigh viscosity High viscosity
Typical Applications:
Industrial applicationsSuitable for industrial use and high strengthWear resistant and other products
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Industrial applications | Suitable for industrial use and high strength | Wear resistant and other products |
| Properties: | wear resistant | high strength | high viscosity | High viscosity |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Relative viscosity | --- | GB/T 1632-93 | 3.00±0.03 | --- |
| density | --- | GB 1033-86 | 1.157 | --- |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | --- | GB 9341-88 | 66.8 | R |
| Shrinkage rate | --- | GB/T 1043-93 | 1.47 | % |
| Bending modulus | --- | GB 9341-88 | 2065 | Mpa |
| Impact strength of cantilever beam gap | --- | IEC (CTI) | 21.4 | KJ/m |
| bending strength | --- | GB 9341-88 | 86.3 | Mpa |
| Elongation at Break | --- | GB 1040-92 | 151.8 | % |
| tensile strength | --- | GB 1040-92 | 66.1 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.82MPa | --- | 75.0 | °C |
| Melting temperature | --- | --- | 218-224 | °C |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | --- | GB 1044-70 | 1.5*10 | Ω.cm |
| --- | GB 1044-70 | 2.8*10 | Ω | |
| Dielectric constant | --- | GB 1044-70 | 1.5 | --- |
| Surface resistivity | --- | --- | 9.0*10 | Ω |
| --- | GB 1044-70 | 7.4*10 | Ω | |
| Dielectric loss | --Tangent | GB 1044-70 | 4.2*10 | --- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.