ABS Novodur® HH-106 BK10009 INEOS STYRO THAILAND
34
- Properties:heat-resisting
- Usages:Electronic fieldAutomotive sectorAutomotive interior partsApplication in the automotive field
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ASTM D570 | 0.3 % | |
melt mass-flow rate | ASTMD1238 | 7.0 g/10min | |
Melt volume flow rate | ISO1133 | 7.00 cm3/10min | |
Shrinkage rate | ASTMD955 | 0.55 % | |
ISO294-4 | 0.40to0.70 % | ||
Water absorption rate | ISO62 | 0.25 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Yield tensile strength | ISO 527-2 | 520 kg/cm | |
Tensile strength at break | ISO 527-2 | 390 kg/cm | |
ISO 527-2 | 3.0 % | ||
elongation | ISO 527-2 | 25 % | |
Tensile modulus | ISO 527-2 | 25000 kg/cm | |
bending strength | ISO 178 | 770 kg/cm | |
Flexural modulus | ISO 178 | 24000 kg/cm | |
Rockwell hardness | 110 R | ||
vicat | ISO 306 | 103 °C | |
ISO2039-1 | 102 Mpa | ||
Tensile modulus | ASTMD638 | 2500 Mpa | |
ISO527-2 | 2400 Mpa | ||
tensile strength | ASTMD638 | 52.0 Mpa | |
Tensile stress | ISO527-2 | 51.0 Mpa | |
Tensile strain | ISO527-2 | 3.0 % | |
elongation | ASTMD638 | 3.0 % | |
Nominal tensile fracture strain | ISO527-2 | 9.0 % | |
Flexural modulus | ASTMD790 | 2400 Mpa | |
ISO178 | 2400 Mpa | ||
bending strength | ASTMD790 | 77.2 Mpa | |
Bending stress | ISO178 | 72.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179 | 100 kJ/m² | |
ISO179 | 190 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | ASTMD257 | >1.0E+15 ohms·cm | |
IEC60093 | 1E+15 ohms·cm | ||
Electrical strength | IEC60243-1 | 39 KV/mm | |
CTI | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO11359-2 | 9E-05 cm/cm/°C | ||
thermal conductivity | DIN52612 | 0.17 W/m/K | |
maximum service temperature | 85 °C | ||
ISO75-2/B | 107 °C | ||
ISO75-2/A | 99.0 °C | ||
vicat | ISO306/A50 | 115 °C | |
ISO306/B50 | 106 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.