Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ASTM D1238 | 1.8 g/10 min |
melt mass-flow rate | | ASTM D1238 | 20 g/10 min |
Shrinkage rate | | ASTM D955 | < 0.40 % |
Water absorption rate | | ASTM D570 | < 0.30 % |
Shrinkage rate | | ASTMD995 | <0.40 % |
Water absorption rate | | ASTMD570 | <0.30 % |
| | ASTMD1238 | 1.8 g/10min |
| | ASTMD1238 | 20 g/10min |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 115 R |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 77.5 Mpa |
Impact strength of cantilever beam gap | | ASTM D256 | 200 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 180 J/m |
Rockwell hardness | | ASTM D785 | 115 |
tensile strength | | ASTM D638 | 44.1 Mpa |
tensile strength | | ASTM D638 | 37.3 Mpa |
elongation | | ASTM D638 | 30 % |
elongation at break | | ASTMD638 | 30 % |
bending strength | | ASTMD790 | 76 Mpa |
Flexural modulus | | ASTMD790 | 2550 Mpa |
Impact strength of cantilever beam gap | | ASTMD256 | 220 J/m |
tensile strength | | ASTMD638 | 44 Mpa |
Flexural modulus | | ASTM D790 | 27000 Mpa |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
fire rating | | UL-94 | 1.50mm HB |
Electrical performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD257 | 1E+22 Ω.cm |
Dielectric Strength | | ASTMD149 | 22 KV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D648 | 85 °C |
vicat | | ASTM D1525 | 103 °C |
High arc combustion index (HAI) | | UL 746 | 200 |
High Voltage Arc Traceability Rate (HVTR) | | UL 746 | 0.00 mm/min |
Hot wire ignition (HWI) | | UL 746 | 18 sec |
UL flame retardant rating | | UL 94 | HB |
| | ASTMD648 | 85 °C |
vicat | | ASTM1525 | 103 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.