| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23℃ | ASTM D256 | 83.3 | J/m |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 182 | Mpa | |
| Bending modulus | ASTM D790 | 8515 | Mpa | |
| Tensile strain | Break | ASTM D638 | 3.4 | % |
| tensile strength | ASTM D638 | 116 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | DSC | 223 | °C | |
| Hot deformation temperature | 1.80 MPa | ASTM D648 | 205 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 260°C,2.16Kg | ASTM D1238 | 21.3 | g/10min |
| Shrinkage rate | TD | ASTM D955 | 0.5-0.9 | % |
| MD | ASTM D955 | 0.3-0.6 | % | |
| Water absorption rate | 110℃/1hrs | ASTM D570 | 0.07 | % |
| density | ASTM D792 | 1.525 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | 10000000000000000 | Ω-cm | |
| Dielectric strength | ASTM D149 | 20 | KV/mm | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.