| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Transmittance rate | 1000μm | ISO 13468-2 | 89.0 | % |
| Refractive index | ISO 489 | 1.58 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 65 | kJ/m² |
| -30°C | ISO 179/1eA | 14 | kJ/m² | |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 75 | kJ/m² |
| -30°C | ISO 180/1A | 12 | kJ/m² | |
| bending strength | 23°C | ISO 178 | 98.0 | Mpa |
| Tensile creep modulus | 1000Hr | ISO 899-1 | 1900 | Mpa |
| Bending modulus | 23°C | ISO 178 | 2350 | Mpa |
| Tensile modulus | 23°C | ISO 527-2 | 2400 | Mpa |
| Tensile creep modulus | 1Hr | ISO 899-1 | 2200 | Mpa |
| Elongation at Break | 23°C | ISO 527-2 | >50 | % |
| tensile strength | 23°C | ISO 527-2 | 66.0 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 6.5E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 6.5E-05 | cm/cm/°C | |
| Hot deformation temperature | 1.80MPaAnnealed | ISO 75-2/Af | 124 | °C |
| Vicat softening temperature | ISO 306/B50 | 143 | °C | |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 136 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD2.0mm | ISO 294-4 | 0.70 | % |
| MD2.0mm | ISO 294-4 | 0.65 | % | |
| density | ISO 1183 | 1.2 | g/cm³ | |
| Water absorption rate | (23°C,50RH) | ISO 62 | 0.12 | % |
| (23°C,24hr) | ISO 62 | 0.30 | % | |
| melt mass-flow rate | 300℃/1.2Kg | ISO 1133 | 19.0 | cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 250 | V |
| 23°C | IEC 60250 | 5E-04 | 100HZ | |
| Dielectric constant | 23°C | IEC 60250 | 3.00 | 1MHz |
| Dissipation factor | 23°C | IEC 60250 | 9E-03 | 1MHz |
| Dielectric strength | IEC 60243-1 | 25 | KV/mm | |
| Surface resistivity | IEC 60093 | 1E+16 | Ω.cm | |
| Volume resistivity | IEC 60093 | 1E+15 | Ω.cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 116 | Mpa | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | V-2 | 0.75mm | |
| UL -94 | HB | 3.00mm | ||
| UL -94 | HB | 6.00mm | ||
| UL -94 | V-2 | 1.50mm | ||
| UL -94 | V-2 | 2.60mm | ||
| UL -94 | HB | 2.70mm | ||
| Extreme Oxygen Index | ISO 4589-2 | 27 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.