PBT 4115-202FV ZHANGZHOU CHANGCHUN
160
Form:Granules | Grade:Enhanced level
Properties:
wear resistantGlass fiber reinforcedFlame retardant
Typical Applications:
Fiber grade
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Fiber grade |
| Properties: | wear resistant | Glass fiber reinforced | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | ASTM D638 | 900-1100 | kg/cm | |
| Elongation at Break | ASTM D638 | 2.5-4.5 | % | |
| bending strength | ASTM D790 | 1400-1800 | kg/cm | |
| Impact strength of cantilever beam gap | 切口1/4″ | ASTM D256 | 4-7 | kg-cm/cm |
| Bending modulus | ASTM D790 | ≥45000 | kg/cm | |
| Shore hardness | ASTM D785 | 93 | M-scale | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Flame resistance | 0.8mm | UL 94 | V-0 | |
| Melting temperature | DSC | 225 | °C | |
| Linear coefficient of thermal expansion | ASTM D696 | 5.5 | ||
| Hot deformation temperature | 18.6kg/cm | ASTM D648 | 205(220) | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Fiberglass content | Ash | 15 | % | |
| Water absorption rate | 24hr immersion | ASTM D570 | 0.03 | % |
| Shrinkage rate | Across Flow,- | ASTM D955 | 0.9-1.3 | % |
| Flow,- | ASTM D955 | 0.2-0.6 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Induced positive connection | ASTM D150 | 0.001 | 60Hz | |
| Arc resistance | ASTM D495 | 90 | sec | |
| Dielectric constant | ASTM D150 | 5.5 | 60Hz | |
| Dielectric strength | 2mm | ASTM D149 | >20 | KV/mm |
| Volume resistivity | ASTM D257 | >10 | Ω | |
| ASTM D257 | >10 | Ω-cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.