PES LUVOCOM® 1100-8401 LEHVOSS Group
0
- Usages:Electrical and electronic applicationsmedical and nursing suppliesfilmfood containerssports goodsmoldsmoldstoolscontainersaerospace applicationsmoldsmachinesmechanical components
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 2.17 g/cm³ | |
Melt volume flow rate | ISO 1133 | 10.0 cm³/10min | |
Shrinkage rate | DIN 16901 | 0.30to0.60 % | |
Water absorption rate | <0.10 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Flexural modulus | ISO 178 | 4500 MPa | |
Tensile modulus | ISO 527-2 | 5500 MPa | |
tensile strength | Break | ISO 527-2 | 80.0 MPa |
Tensile strain | Yield | ISO 527-2 | 2.8 % |
bending strength | ISO 178 | 115 MPa | |
Bending Strain | ISO 178 | 3.3 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | 4.0 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 30 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | >1.0E+10 ohms | |
insulation resistance | IEC 60167 | >1.0E+10 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/A | 215 °C | |
Heat distortion temperature | ISO 75-2/A | 195 °C | |
Continuous use temperature | UL 746B | 180 °C | |
maximum service temperature | 220 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top