PA66 Nylon-273G OSTERMAN USA
Properties:
Filler glass fiber reinforced material 33% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 33% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 130 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | HB | |
| 3.0mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | ASTM D638 | 138 | MPa | |
| elongation | Break | ASTM D638 | 3.0 | % |
| Bending modulus | ASTM D790 | 9310 | MPa | |
| bending strength | ASTM D790 | 262 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 249 | °C |
| Melting temperature | ASTM D789 | 260 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.35 | g/cm³ | |
| Shrinkage rate | MD | ASTM D955 | 0.30to0.50 | % |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ASTM D785 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.