Share
Add to compare

PA66 POLYNIL® P36/4 Celanese Corporation

Typical Applications:
composite
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:composite

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30°CISO 179/1eA4.5kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA5.5kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU无断裂
Impact strength of cantilever beam gap-30°CISO 180/A4.5kJ/m²
Impact strength of cantilever beam gap23°CISO 180/A5.5kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating3.2mmUL 94V-2
Extreme Oxygen IndexISO 4589-228%
Hot filament ignition temperature3.2mmIEC 60695-2-13750°C
Hot filament ignition temperature0.8mmIEC 60695-2-13775°C
Burning wire flammability index3.2mmIEC 60695-2-12850°C
Burning wire flammability index0.8mmIEC 60695-2-12750°C
UL flame retardant rating0.8mmUL 94V-2
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
bending strength23°CISO 178120MPa
Bending modulus23°CISO 1782850MPa
Tensile strainBreak,23°CISO 527-250%
tensile strengthYield,23°CISO 527-281.0MPa
Tensile modulus23°CISO 527-23100MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Ball Pressure TestMelting TemperatureIEC 60695-10-2258°C
Ball Pressure Test165°CIEC 60695-10-2通过
Ball Pressure Test125°CIEC 60695-10-2通过
Vicat softening temperatureISO 306/B240°C
Continuous use temperatureIEC 6021685.0°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A72.0°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B225°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rateSaturation,23°CISO 628.5%
Water absorption rate23°C,24hrISO 621.5%
density23°CISO 11831.14g/cm³
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace index3.20mm,SolutionAIEC 60112PLC 0
Dielectric strength2.00mmIEC 60243-118kV/mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.