Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.87 g/cm³ |
Water absorption rate | Equilibrium | ASTM D570 | 0.60 % |
hardness | Test Condition | Test Method | Test Result |
---|
Barcol Hardness | | | 46 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | ASTM D229 | 1.0 min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D638 | 68.9 MPa |
tensile strength | | ASTM D638 | 34.5 MPa |
bending strength | | ASTM D790 | 124 MPa |
bending strength | | ASTM D790 | 96.5 MPa |
compressive strength | | ASTM D695 | 221 MPa |
shear strength | | ASTM D229 | 96.5 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 430 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 20 kV/mm |
arc resistance | | ASTM D495 | 150 sec |
dielectric strength | | ASTM D149 | 54000 V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.