PC Latishield 87/28-10A G/20
0
- Properties:Fillerglass fiber reinforced material20%filler by weightsteel filler
- Usages:Cable sheathwire and cable application
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.40to0.60 % | |
ISO 294-4 | 0.20to0.40 % | ||
density | ISO 1183 | 1.44 g/cm³ |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 45 kJ/m² | |
Charpy Notched Impact Strength | ISO 179/1eA | 8.0 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 5100 MPa | |
tensile strength | ISO 527-2/5 | 50.0 MPa | |
Tensile strain | ISO 527-2/5 | 3.0 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | ASTM D257 | 1E+02 ohms | |
Volume resistivity | ASTM D257 | 1E+03 ohms·cm | |
Electromagnetic reflectivity | 90 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/B | 145 °C | |
ISO 75-2/A | 140 °C | ||
vicat | ISO 306/B50 | 150 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top