PC+ABS KumhoSunny PC/ABS HAC8245 Shanghai KumhoSunny Plastics Co., Ltd.
Typical Applications:
Medical and nursing supplies thin-walled components household goods applications in the automotive industry electrical and electronic applications optical applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Medical and nursing supplies | thin-walled components | household goods | applications in the automotive industry | electrical and electronic applications | optical applications |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C4 | ISO 180 | 48 | kJ/m² |
| 3.20mm | ASTM D256 | 600 | J/m | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 无断裂 | |
| Charpy Notched Impact Strength | 23°C | ISO 179 | 50 | kJ/m² |
| -30°C | ISO 179 | 30 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | -- | ASTM D790 | 60.0 | MPa |
| Bending modulus | --2 | ISO 178 | 2000 | MPa |
| -- | ASTM D790 | 2000 | MPa | |
| elongation | Break | ASTM D638 | 80 | % |
| tensile strength | -- | ISO 527-2/50 | 52.0 | MPa |
| -- | ASTM D638 | 50.0 | MPa | |
| bending strength | --2 | ISO 178 | 65.0 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | -- | ASTM D15255 | 112 | °C |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 95.0 | °C |
| Vicat softening temperature | -- | ISO 306/B50 | 110 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | -- | ISO 294-4 | 0.50to0.70 | % |
| MD | ASTM D955 | 0.50to0.70 | % | |
| melt mass-flow rate | 230°C/10.0kg | ASTM D1238 | 25 | g/10min |
| density | -- | ISO 1183 | 1.11 | g/cm³ |
| -- | ASTM D792 | 1.10 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| CSAFileNo | LS66457 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.