PA46 TC155 DSM HOLAND
108
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedThermal stability
Typical Applications:
Home appliance componentsElectronic and electrical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Home appliance components | Electronic and electrical components |
| Properties: | Glass fiber reinforced | Thermal stability |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 10 | kJ/m² |
| -30°C | ISO 179/1eU | 10 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | V-0 | ||
| UL 94 | V-0 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 0.60 | % |
| tensile strength | Break | ISO 527-2 | 55.0 | Mpa |
| Tensile modulus | ISO 527-2 | 11000 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| thermal conductivity | --4 | ASTM E1461 | 5.0 | W/m/K |
| --3 | ASTM E1461 | 1.0 | W/m/K | |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 2.5E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 2.5E-5 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | Flow | ISO 294-4 | 0.30 | % |
| 横向Flow | ISO 294-4 | 0.30 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative permittivity | 10.0 GHz | IEC 60250 | 3.89 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.