PA46 TC154 DSM HOLAND
38
Form:Granules | Grade:Injection grade
Properties:
Flame retardantheat conductionThermal stability
Typical Applications:
Home appliance componentsElectronic and electrical components
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Home appliance components | Electronic and electrical components |
| Properties: | Flame retardant | heat conduction | Thermal stability |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 2.0 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 2.0 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | V-0 | ||
| UL 94 | V-0 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 2.0 | % |
| tensile strength | Break | ISO 527-2 | 55.0 | Mpa |
| Tensile modulus | ISO 527-2 | 5100 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 0.75 mm | UL 746 | 140 | °C |
| thermal conductivity | --4 | ASTM E1461 | 1.0 | W/m/K |
| --3 | ASTM E1461 | 0.50 | W/m/K | |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 4.8E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 4.8E-5 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.9 | % |
| Shrinkage rate | Flow | ISO 294-4 | 0.60 | % |
| 横向Flow | ISO 294-4 | 0.70 | % | |
| density | ISO 1183 | 1.52 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1.0E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 30 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.