AS(SAN) 348Q INEOS STYRO THAILAND
24
Form:Granules | Grade:Injection grade
Properties:
transparent
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | transparent |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| turbidity | ASTM D1003 | <1.0 | % | |
| transmissivity | 550nm | ASTM D1003 | >89.0 | % |
| Refractive index | ISO 489 | 1.569 | ||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ISO 180/A | 1.5 | kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179 | 1.5 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 14 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield,23°C | ISO 527-2 | 70.0 | Mpa |
| bending strength | ISO 178 | 115 | Mpa | |
| Tensile modulus | ISO 527-2 | 3600 | Mpa | |
| Tensile strain | Break,23°C | ISO 527-2 | 2.5 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| thermal conductivity | DIN 52612 | 0.17 | W/m/K | |
| Hot deformation temperature | 0.45MPa,Annealed | ISO 75-2/B | 99.0 | °C |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 7E-05 | cm/cm/°C |
| Vicat softening temperature | ISO 306/B50 | 105 | °C | |
| Hot deformation temperature | 1.8MPa,Annealed | ISO 75-2/A | 86.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melt Volume Flow Rate (MVR) | 220°C/10.0kg | ISO 1133 | 19.0 | cm3/10min |
| density | ISO 1183 | 1.08 | g/cm³ | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % |
| Shrinkage rate | ISO 294-4 | 0.30-0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Dissipation factor | 1MHz | IEC 60250 | 7E-03 | |
| 100Hz | IEC 60250 | 4E-03 | ||
| Dielectric constant | 100Hz | IEC 60250 | 2.90 | |
| Volume resistivity | IEC 60093 | 1E+16 | ohms·cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 160 | Mpa | |
| Rockwell hardness | M-Scale | 77 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.