PCTG DN011 EASTMAN USA
109
Form:Granules | Grade:Injection grade
Properties:
Chemical resistanceHydrolysis resistance
Typical Applications:
Electrical applicationsHousehold daily necessities
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electrical applications | Household daily necessities |
| Properties: | Chemical resistance | Hydrolysis resistance |
Certificates

Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| turbidity | ASTM D1003 | 1.0 | % | |
| Transmittance rate | μm | ASTM D1003 | 92 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | -40°C | ASTM D256 | 77 | J/m |
| 23°C | ASTM D256 | NB | J/m | |
| Bending modulus | 23°C | ASTM D790 | 1800 | Mpa |
| bending strength | 23°C | ASTM D790 | 66 | Mpa |
| Tensile modulus | 23°C | ASTM D638 | 1800 | Mpa |
| Elongation at Break | 23°C | ASTM D638 | 330 | % |
| tensile strength | 23°C | ASTM D638 | 44 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.80MPaUnannealed | ASTM D648 | 64 | °C |
| 0.45MPaUnannealed | ASTM D648 | 73 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.23 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 相对漏电起痕指数 | ASTM D3638 | 600 | V |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ASTM D785 | 105 | R | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 3.00mm | |
| UL -94 | HB | 1.50mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.