PPA FR52G30BL DUPONT USA
238
Form:Granules | Grade:Injection grade
Properties:
High temperature resistanAging resistanceFlame retardant
Typical Applications:
Automotive interior equipmentProfilebuilding materials
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive interior equipment | Profile | building materials |
| Properties: | High temperature resistan | Aging resistance | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | kJ/m² | 45 | |
| -30°C | kJ/m² | 40 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Hot filament ignition temperature | 3.00mm | °C | 775 | -- |
| 0.400mm | °C | 700 | -- | |
| Burning wire flammability index | 3.00mm | °C | 960 | -- |
| 0.400mm | °C | 960 | -- | |
| Flammability level | 1.50mm | V-0 | -- | |
| 0.400mm | V-0 | -- | ||
| Extreme Oxygen Index | % | 37 | -- | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 225 | MPa | ||
| Bending modulus | MPa | 9800 | 10800 | |
| Tensile strain | Break | % | 2.1 | 1.9 |
| tensile strength | Break | 145 | MPa | |
| Tensile modulus | MPa | 10700 | 11300 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD:-40to23°C | cm/cm/°C | 1.8E-05 | -- |
| MD:55to160°C | cm/cm/°C | 1.2E-05 | -- | |
| TD | cm/cm/°C | 6.2E-05 | -- | |
| MD | cm/cm/°C | 1.8E-05 | -- | |
| Melting temperature | °C | 310 | -- | |
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 281 | -- |
| RTI Elec | 3.00mm | °C | 140 | -- |
| 1.50mm | °C | 140 | -- | |
| 0.750mm | °C | 140 | -- | |
| 0.400mm | °C | 140 | -- | |
| Linear coefficient of thermal expansion | TD:-40to23°C | cm/cm/°C | 6E-05 | -- |
| TD:55to160°C | cm/cm/°C | 9.5E-05 | -- | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | % | 0.30 | -- |
| TD | % | 1.0 | -- | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | V | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.