PTFE AD250 Arlon-MED
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Compressive modulus | ASTM D695 | 2520 | MPa | |
| Bending modulus | 23°C | ASTM D790 | 3720 | MPa |
| Tensile modulus | 23°C3 | ASTM D638 | 3560 | MPa |
| 23°C2 | ASTM D638 | 4870 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | YAxis:0to100°C | Internal Method | 1.5E-05 | cm/cm/°C |
| XAxis:0to100°C | Internal Method | 1.2E-05 | cm/cm/°C | |
| thermal conductivity | 100°C | ASTMC177 | 0.24 | W/m/K |
| Linear coefficient of thermal expansion | ZAxis:0to100°C | 9.5E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.070 | % |
| density | ASTM D792A | 2.40 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | ASTM D495 | >180 | sec | |
| Dissipation factor | 10.0GHz | Internal Method | 1.8E-03 | |
| Dielectric constant | 23°C | Internal Method | 2.50 | |
| Volume resistivity | Internal Method | 1.2E+15 | ohms·cm | |
| Surface resistivity | Internal Method | 4.5E+07 | ohms | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| Peel strength | Internal Method | -2.5 | kN/m | |
| tensile strength | TD:Yield | ASTM D882 | 119 | MPa |
| MD:Yield | ASTM D882 | 144 | MPa | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Breakdown voltage strength | ASTM D149 | >45000 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.