Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D-792 | 1.07 g/cm |
density | | ISO 1183 | 1070 Kg/m |
Shrinkage rate | | ASTM D-955 | 0.40-0.70 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ASTM D-1238 | 12 g/10min |
melt mass-flow rate | | ISO 1133 | 10.0 cm |
Water absorption rate | | ISO 62 | 0.36 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO 527-2 | 45.0 MPa |
Tensile strain | | ASTM D-638 | 30 % |
Tensile strain | | ISO 527-2 | 18 % |
Flexural modulus | | ASTM D-790 | 2250 MPa |
bending strength | | ASTM D-790 | 71.7 MPa |
Charpy Notched Impact Strength | | ISO 179/1eA | 1.70 KJ/m |
Charpy Notched Impact Strength | | ISO 179/1eA | 15.8 KJ/m |
Charpy Notched Impact Strength | | ISO 179/1eU | 35.5 KJ/m |
Charpy Notched Impact Strength | | ISO 179/1eU | No Break KJ/m |
Impact strength of cantilever beam gap | | ASTM D-256 | 224 J/m |
Impact strength of cantilever beam gap | | ASTM D-256 | 165 J/m |
Rockwell hardness | | ASTM D-785 | 106 R-Scale |
Tensile modulus | | ISO 527-2 | 2200 MPa |
tensile strength | | ASTM D-638 | 46.9 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
relative permittivity | | IEC 60250 | 3.20 |
Dielectric loss | | IEC 60250 | 0.033 |
Compared to the Leakage Traceability Index (CTI) | | IEC 60112 | 600 |
dielectric strength | | IEC 60243-1 | 42 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D-648 | 92.2 ℃ |
Glass Transition Temperature | | ISO 11357-2 | 110 ℃ |
vicat | | ASTM D-1525 | 106 ℃ |
vicat | | ISO 306 | 95.9 ℃ |
Linear coefficient of thermal expansion | | ISO 11359-2 | 0.000080 cm/cm/℃ |
Linear coefficient of thermal expansion | | ISO 11359-2 | 0.000080 cm/cm/℃ |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | ISO 1210 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.