Unspecified ADDILENE J 490 S ADDIPLAST FRANCE
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179/1eA | 10 | kJ/m² | |
| Impact strength of simply supported beam without notch | ISO 179/1eU | 无断裂 | ||
| Impact strength of cantilever beam gap | ISO 180/1A | 10 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-2 | |
| Hot filament ignition temperature | IEC 60695-2-13 | 960 | °C | |
| Extreme Oxygen Index | ISO 4589-2 | 26 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break | ISO 527-2 | 26.0 | MPa |
| Tensile strain | Break | ISO 527-2 | >100 | % |
| Bending modulus | ISO 178 | 1000 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/Af | 51.0 | °C |
| Vicat softening temperature | ISO 306/A50 | 152 | °C | |
| Melting temperature | ISO 3146 | 165to168 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 12 | g/10min |
| density | ISO 1183/A | 0.940 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 0 | |
| Surface resistivity | IEC 60093 | 1E+13 | ohms | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 43 | kV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | ISO 868 | 65 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.