Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.24 g/cm³ | |
Shrinkage rate | ISO 294-4 | 0.2-0.6 % | |
ISO 294-4 | 0.3-0.8 % | ||
melt mass-flow rate | ISO 1133 | 14 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | 13 kJ/m² | |
tensile strength | ISO 527-2 | 55 MPa | |
elongation at break | ISO 527-2 | 4 % | |
Tensile modulus | ISO 527-2 | 2200 MPa |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL -94 | V-0 1.50mm | |
UL -94 | V-0 3.00mm | ||
GWIT | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/B50 | 135 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App