Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D1505 | 0.920 g/cm³ |
Degree of crosslinking | | ASTM D2765A | >80 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTM D638 | >19.7 MPa |
elongation | Break | ASTM D638 | >500 % |
aging | Test Condition | Test Method | Test Result |
---|
Change rate of tensile strength in air | | ASTM D573 | <10 % |
Change rate of ultimate elongation in air | | ASTM D573 | <10 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D257 | >1.0E+16 ohms·cm |
dielectric strength | | ASTM D149 | >22 kV/mm |
dielectric constant | | ASTM D150 | 2.30 |
Dissipation Factor | | ASTM D150 | 3E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
thermosetting | | IEC 60811-2-1 | <180 % |
thermosetting | | IEC 60811-2-1 | <15 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.