PA6 BG-30S EMS-CHEMIE SWITZERLAND

56

Form:Granules | Grade:Injection grade

Properties:
Glass fiber reinforcedHigh impact resistance
Typical Applications:
Home appliance componentsAutomotive interior partsElectrical applications
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Home appliance components | Automotive interior parts | Electrical applications
Properties:Glass fiber reinforced | High impact resistance

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30℃-30°CISO 179/1eA8kJ/m²
Charpy Notched Impact Strength23℃23°CISO 179/1eA11kJ/m²
Impact strength of simply supported beam without notch-30℃-30°CISO 179/1eU65kJ/m²
Impact strength of simply supported beam without notch23℃23°CISO 179/1eU75kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Ball Pressure TestISO 2039-1210Mpa
Tensile modulusISO 527-29500Mpa
tensile strengthBreakBreakISO 527-2185Mpa
Tensile strainBreakBreakISO 527-25%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8 MPa,Unannealed264 psi, UnannealedISO 75-2/A205°C
Hot deformation temperature8.0 MPa,Unannealed1160 psi, UnannealedISO 75-2/C135°C
Continuous use temperature---- 33ISO 257890.0 to 110°C
Continuous use temperature---- 44Internal Method160°C
Melting temperatureISO 11357-3222°C
Linear coefficient of thermal expansionMDFlowISO 11359-20.0000201/℃
Linear coefficient of thermal expansionTDTransverseISO 11359-20.000111/℃
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.35g/cm³
Shrinkage rateTDAcross FlowISO 294-40.8%
Shrinkage rateMDFlowISO 294-40.1%
Water absorption rateSaturation,23℃Saturation, 73°FISO 627%
Water absorption rateEquilibrium,23℃,50% RHEquilibrium, 73°F, 50% RHISO 622%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093--ohms
Volume resistivityIEC 60093100000000000000ohms·cm
Dielectric strengthIEC 60243-140KV/mm
Compared to the anti leakage trace indexIEC 60112V
flame retardant performanceTest ConditionTest MethodTest ResultTest Unit
Flammability levelUL 94HB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.