PES F2150 Dongguan Hongwen
3
Form:Powder
Properties:
Good chemical resistanceHigh thermal deformation Flame retardantExcellent electrical perfGood mechanical performanExcellent film-forming pr
Typical Applications:
New energy vehicle batterWater filtration membraneelectrical outlet
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | New energy vehicle batter | Water filtration membrane | electrical outlet |
| Properties: | Good chemical resistance | High thermal deformation | Flame retardant | Excellent electrical perf | Good mechanical performan | Excellent film-forming pr |
| Form: | Pellets |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| density | ISO1183 | 1.3 | g/cm³ | |
| Saturated water absorption rate | 23℃,50%RH | ISO62 | 0.8 | % |
| Melt index | 380℃,2.16kg | ISO 1133 | 15-25 | g/10min |
| Moulding shrinkage | ISO 2577 | 0.86 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | 50mm/min | ISO 527-1/-2 | 88 | MPa |
| Tensile modulus | 1mm/min | ISO 527-1/-2 | 2700 | MPa |
| elongation at yield | 50mm/min | ISO 527-1/-2 | 6.5 | % |
| bending strength | 2mm/min | ISO 178 | 120 | MPa |
| Bending modulus | 2mm/min | ISO 178 | 2650 | MPa |
| Izod Notched Impact Strength | ISO 180/A | 6.8 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa, 4mm | ISO 75-1/-2 | 205 | ℃ |
| Glass transition temperature | 10℃/min | ISO 11357-1/-2 | 225 | ℃ |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | 100V | IEC 60093 | >1E+15 | Ω |
| Surface resistivity | 100V | IEC 60093 | >1E+13 | Ω |
| Relative dielectric constant | 100HZ | IEC 60250 | 3.9 | |
| dielectric dissipation factor | 1MHZ | IEC 60250 | 3.8 | E-4 |
| Dielectric strength | 60*60*1mm3 | IEC 60243-1 | 37 | KV/mm |
| Comparative Tracking Index | IEC 60112 | 125 | ||
| flame retardancy | Test Condition | Test Method | Test Result | Test Unit |
| Flame retardancy | 1.5mm | UL94 | Class V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.