PPO/PA GTX914-14101 SABIC EU
57
Form:Granules
Properties:
Hydrolysis resistanceHigh temperature resistanDimensional stabilityHigh mobilityExcellent impact resistanTemperature resistanceChemical properties and p
Typical Applications:
Industrial machineryElectrical applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Industrial machinery | Electrical applications |
| Properties: | Hydrolysis resistance | High temperature resistan | Dimensional stability | High mobility | Excellent impact resistan | Temperature resistance | Chemical properties and p |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Extreme Oxygen Index | ISO 4589 | 21 | % | |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | DIN 53495 | 3.50 | % | |
| density | ISO 1183 | 1.09 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | 50mm/min,Break | ISO 527 | 60 | % |
| 50mm/min,Yield | ISO 527 | 7.5 | % | |
| tensile strength | 50mm/min,Break | ISO 527 | 55 | Mpa |
| 50mm/min,Yield | ISO 527 | 55 | Mpa | |
| Impact strength of cantilever beam gap | -30℃ 有Notched | ISO 180/1A | 15 | KJ/m |
| 23℃ 有Notched | ISO 180/1A | 30 | KJ/m | |
| Charpy Notched Impact Strength | 23℃ | ISO 179/2C | 30 | KJ/m |
| Bending modulus | 2mm/min | ISO 178 | 2000 | Mpa |
| bending strength | 2mm/min | ISO 178 | 80 | Mpa |
| Tensile modulus | 1mm/min | ISO 527 | 2100 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | B/120 | ISO 306 | 195 | °C |
| B/50 | ISO 306 | 190 | °C | |
| A/50 | ISO 306 | 245 | °C | |
| Linear coefficient of thermal expansion | DIN 53752 | 9E-05 | 1/℃ | |
| thermal conductivity | DIN 52612 | 0.23 | W/m℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | H358/30 | ISO 2039/1 | 90 | Mpa |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 1MHz | IEC 250 | 0.0240 | |
| 50Hz | IEC 250 | 0.0720 | ||
| Dielectric strength | IEC 243 | 20.0 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.