TPV X10075B TEKNOR APEX BELGIUM

8

Form:Granules | Grade:Weather resistant grade

Typical Applications:
Automotive External Parts
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Automotive External Parts

Certificates

No Data...

Technical Data Sheet

Filling analysisTest ConditionTest MethodTest ResultTest Unit
Apparent viscosity200°C,206sec^-1ASTM D3835190Pa·s
elastomerTest ConditionTest MethodTest ResultTest Unit
tensile strength横向Flow:100%StrainISO 372.80Mpa
tensile strengthFlow:100%StrainISO 373.50Mpa
tensile strength横向Flow:BreakISO 376.10Mpa
tensile strengthFlow:BreakISO 375.40Mpa
elongation横向Flow:BreakISO 37490%
elongationFlow:BreakISO 37410%
tear strength横向FlowISO 34-130kN/m
Permanent compression deformation23°C,22hrISO 81524%
Permanent compression deformation70°C,22hrISO 81534%
Permanent compression deformation125°C,70hrISO 81550%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Friction coefficientASTM D18940.40to0.50
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShoreA,5Sec,挤塑ISO 86873
Shore hardnessShoreA,5Sec,InjectionISO 86875
agingTest ConditionTest MethodTest ResultTest Unit
Change rate of hardness (Shore) in the airShoreA,135°C,1008hrISO 1880.0
Change rate of hardness (Shore) in the airShoreA,150°C,168hrISO 188-3.0
Volume change125°C,70hr,在IRM903油中ISO 181770%
Change rate of tensile strength in air135°C,1008hr,Across FlowISO 188-15%
Change rate of tensile strength in air100%Strain135°C,1008hr,Across FlowISO 1885.0%
Change rate of tensile strength in air150°C,168hr,Across FlowISO 188-25%
Change rate of tensile strength in air100%Strain150°C,168hr,Across FlowISO 1880.0%
Tensile stress change rate135°C,1008hr,BreakISO 188-20%
Tensile stress change rate150°C,168hr,BreakISO 188-25%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.