PPS LUVOCOM® 1301-0915-W
0
- Properties:Fillerscarbon fiber reinforced materials
- Usages:Applications in medicalnursing suppliesbusiness equipmentengineering accessoriestextile applicationsand automotive fields
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | DIN16901 | 0.20到0.50 % | |
density | ISO1183 | 1.48 g/cm³ | |
Water absorption rate | <0.050 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile strain | Yield | ISO527-2 | 1.5 % |
Flexural modulus | ISO178 | 10000 MPa | |
Bending stress | ISO178 | 120 MPa | |
Bending Strain | ISO178 | 2.0 % | |
Tensile stress | Break | ISO527-2 | 80.0 MPa |
Tensile modulus | ISO527-2 | 11000 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1fU | 15 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC60093 | <1.0E+4 ohms | |
insulation resistance | IEC60167 | <1.0E+5 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO75-2/A | 220 °C | ||
Continuous use temperature | UL746B | 220 °C | |
Maximum operating temperature - SharrTerm | 240 °C | ||
DIN53752 | 3E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.